Dental
Chamber Furnaces for Annealing after Laser Sintering
![]() |
![]() |
Chamber furnace N 41/H | Chamber furnace N 7/H with protective gas box |
For the annealing of frameworks made of cobalt-chromium after laser sintering the chamber furnaces N 7/H - N 41/H are used. These furnaces will be equipped with a gax-box as well as an automatic gas-supply system for one non-flammable protective gas, e.g. Argon. Please ask for our catalog “Thermal Process Technology”.
- Tmax 1150 °C
- The recommended working temperature is max. 1100 °C. Higher wear and tear of the gassing box has to be expected at higher working temperatures up to 1150 °C
- Three-sided heating from both sides and the bottom
- Heating elements on support tubes ensure free heat radiation and a long service life
- Bottom heating protected by heat-resistant SiC plate
- Multi-layer insulation with high-quality lightweight refractory bricks in the furnace chamber
- Exhaust opening in the side of the furnace, or on back wall of chamber furnace in the N 41/H models and higher
- Chamber furnaces N 7/H - N 17/HR are designed as tabletop models
- Base included with chamber furnace N 41/H
- Protective gas boxes for inert gas atmosphere with additional thermocouple, type K
- Solenoid valve, controlled via the extra function of the controller B400
- Digital temperature indicator for measuring the temperature inside the gassing box
- Charging plate and annealing and hardening foils
- Defined application within the constraints of the operating instructions
- NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Model | Tmax | Inner dimensions protective gas box in mm | Volume | Outer dimensions in mm | Connected | Electrical | Weight | Minutes | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
°C | w | d | h | in l | W | D | H | load kW | connection* | in kg | to Tmax2 | |
N 7/H | 1150 | 180 | 190 | 90 | 9 | 800 | 650 | 600 | 3.0 | 1-phase | 60 | 180 |
N 11/H | 1150 | 180 | 290 | 90 | 11 | 800 | 750 | 600 | 3.5 | 1-phase | 70 | 180 |
N 11/HR | 1150 | 180 | 290 | 90 | 11 | 800 | 750 | 600 | 5.5 | 3-phase1 | 70 | 120 |
N 17/HR | 1150 | 180 | 440 | 90 | 17 | 800 | 900 | 600 | 6.4 | 3-phase1 | 90 | 120 |
N 41/H | 1150 | 280 | 380 | 200 | 41 | 1040 | 1250 | 1340 | 15.0 | 3-phase | 260 | 120 |
1Heating only between two phases *Please see page 18 for more information about supply voltage 2If connected at 230 V 1/N/PE rsp. 400 V 3/N/PE |